葡甘露聚糖检测试剂盒 Glucomannan Assay Kit 货号:K-GLUM Megazyme试剂盒

葡甘露聚糖检测试剂盒

英文名:Glucomannan Assay Kit

货号:K-GLUM

规格:50 Assays per kit

市场价: 5100

The Glucomannan test kit is suitable for the measurement and analysis of Glucomannan in plant products and food.

UV-method for the determination of Glucomannan in plant
products, foodstuffs and other materials

Principle:
(β-mannanase)
(1) Ac-Glucomannan + H2O → Ac-glucomanno-oligomers

(pH 12.5)
(2) Ac-Glucomanno-oligomers + H2O → glucomanno-oligomers
+ acetate

(β-glucosidase + β-mannosidase)
(3) Glucomanno-oligomers + H2O → D-glucose + D-mannose

(hexokinase)
(4) D-glucose + D-mannose + ATP → G-6-P + M-6-P + ADP

(glucose-6-phosphate dehydrogenase)
(5) G-6-P + NADP+ → gluconate-6-phosphate + NADPH + H+

(phosphomannose isomerase) (phosphoglucose isomerase)
(6) M-6-P → F-6-P → G-6-P

Kit size: 50 assays
Method: Spectrophotometric at 340 nm
Total assay time: 120 min
Detection limit: 1-100% of sample weight
Application examples:
Jelly sweets, cosmetics, food gums and other materials
Method recognition: Novel method

Advantages

  • Very cost effective
  • Only enzymatic kit available
  • Simple format
  • All reagents stable for > 2 years after preparation
  • Mega-Calc™ software tool is available from our website for hassle-free raw data processing
  • Standard included

Q1. Should the pH of the sample be adjusted even for samples in acidic media?

The pH of the assay solution after the sample is added should be the same as that of the assay buffer that is supplied with the kit.
Low sample volumes (e.g. 0.1 mL) are not likely to affect the pH of the assay solution and therefore may not require pH adjustment.
Samples above 0.1 mL are more likely to affect the pH of the assay solution and therefore the pH of these samples should be adjusted as described in the data booklet, prior to addition to the assay.

Q2. Sometimes a negative absorbance change is obtained for the blank samples, is this normal? Should the real value (negative absorbance change) or “0” be used in the calculation of results?

Sometimes the addition of the last assay component can cause a small negative absorbance change in the blank samples due to a dilution effect and in such cases it is recommended that the real absorbance values be used in the calculation of results.

Q3. There is an issue with the performance of the kit; the results are not as expected.

If you suspect that the Megazyme test kit is not performing as expected such that expected results are not obtained please do the following:

  1. Ensure that you have tested the standard sample that is supplied with the Megazyme test kit.
  2. Send the results of the kit standard, blank samples and the results obtained for your sample, in the relevant MegaCalc spreadsheet (if available) to Megazyme (cs@megazyme.com). Where available the relevant MegaCalc spreadsheet can be downloaded from where the product appears on the Megazyme website.
  3. State the kit lot number being used (this is found on the outside of the kit box).
  4. State which assay format was used (refer to the relevant page in the kit booklet if necessary).
  5. State exact details of any modifications to the standard procedure that is provided by Megazyme.
  6. State the sample type and describe the sample preparation steps if applicable.